Handicap Door Operator Installation in Gatineau

A medical clinic in Gatineau needed a fully accessible entrance. We wired and installed a Camden bi-directional operator system with an interior handicap paddle — then tested the full cycle on video. Here’s the job, start to finish.

Aluminum storefront clinic entrance held open during an automatic door operator installation in Gatineau
Gatineau clinic storefront entrance during the accessible automatic door operator install.
Category: Automatic Door Systems Location: Gatineau, QC Property type: Commercial Completed in: One day, on site

A medical clinic in Gatineau needed its entrance fully accessible. We ran the control wiring through the vestibule frame, mounted the operator hardware, and wired a Camden bi-directional sequencer to the interior handicap paddle so the doors open in sync. Here’s the job, start to finish.

This Gatineau clinic needed an entrance that met accessibility requirements from day one — a vestibule-style commercial entrance that had to operate in the correct sequence, triggered by an interior handicap paddle. That’s not a plug-and-play job: it means running low-voltage wiring cleanly through the frame, mounting the operator arms so they clear the header, and programming the control logic so the outer and inner doors don’t fight each other.

The Repair

We started by routing the control cable through a drilled channel in the door frame, keeping the run tight to the jamb so nothing snags when the door cycles. The operator arm and motor assembly were mounted above the header and set to the correct opening force and speed for a commercial entrance. The key piece of the job was the Camden switching network and bi-directional sequencer, wired and labeled specifically for the interior handicap paddle so it fires the correct relay for that door only — get the relay assignment wrong and you end up with both doors trying to open at once, or the wrong door responding to the paddle. Once the wiring was confirmed clean, we tested the full cycle repeatedly: paddle press, sequencing, hold-open time, and full close, until it ran the same way every time. A job like this often overlaps with automatic door repair work, since the same operator hardware needs regular adjustment once it’s in daily commercial use.

Multi-conductor low-voltage cable pulled through a drilled hole in a commercial door frame
Control cable routed through a drilled channel in the door frame so nothing snags when the door cycles.

Clean, protected wiring is what keeps a commercial operator reliable once it sees daily clinic traffic. Exposed runs at an entrance do not last, and a snagged cable is one of the fastest ways an accessibility system goes offline after opening day.

Overhead swing door operator and drive arm exposed in the header above a commercial storefront entrance
Overhead swing operator and drive arm mounted in the header and set for commercial opening force and speed.

With the header hardware set, we moved to the control side of the job: labeling relays on the Camden CX-12 and confirming the interior paddle only fires the intended sequence. Commercial clinic traffic also means the force and timing have to be calibrated for daily use, not a residential default — too aggressive and the door slams; too soft and it fails accessibility timing.

Camden CX-12 switching network and bi-directional sequencer board wired for an accessibility push paddle
Camden CX-12 switching network and bi-directional sequencer wired for the interior accessibility paddle.

Once the wiring was confirmed clean, we tested the full cycle repeatedly before recording a walk-up of the finished entrance in motion so the clinic has a clear record of the operator cycling correctly.

On-site test: the operator cycling the Gatineau clinic entrance open after wiring and sequencing.

Problems We Solved

  • No accessible entrance in place ahead of the clinic’s patient traffic.
  • Control wiring that needed to be routed cleanly through the frame with no exposed runs.
  • Vestibule doors that had to open in the correct sequence, not simultaneously.
  • Relay assignments on the switching network that had to match the interior paddle exactly.
  • Operator force and timing that needed commercial-grade calibration, not a residential default.

Benefits of the Repair

  • A fully accessible entrance ready for daily clinic use.
  • Clean, protected wiring routed through the frame with no loose runs.
  • Doors sequencing correctly from a single interior paddle press.
  • Operator hardware calibrated for daily commercial traffic.
  • A tested, repeatable cycle — verified on video before we left the site.

Handicap Door Operator Installs Across Ottawa & the Ottawa Valley

Accessible entrances come up constantly in commercial fit-outs — clinics, offices, and storefronts across Gatineau, Orléans, Ottawa and the Ottawa Valley all need entrances that meet accessibility standards, and a vestibule with doors in sequence is one of the more demanding versions of that job. We handle the wiring, the operator hardware and the control logic so the paddle, sensors and doors all work together instead of fighting each other. Whether it’s a new install ahead of an opening date or a repair on hardware that’s stopped sequencing correctly, we can usually get it running in a single visit.

Need a similar install or repair?

Whether you’re fitting out a new commercial entrance or your existing operator has stopped sequencing right, send us a photo and we’ll tell you what it needs — same-day service across Gatineau, Ottawa & the Ottawa Valley.

← Back to the full Before & After Gallery
More Of Our Work

Related Door Repair Projects

FAQ

Handicap Door Operator Installation in Gatineau — FAQs

Common questions about this project and the service behind it.

What's involved in installing a handicap-accessible entrance?
+
Running control wiring through the frame, mounting the operator hardware above the door, and wiring the paddle switch and control relays so the door opens on a press and holds long enough for safe entry.
Why does a vestibule need a bi-directional sequencer?
+
With two sets of doors, a sequencer makes sure the inner and outer doors open and close in the right order instead of both cycling at once, which keeps the vestibule airtight and functioning correctly.
Can this be added to an existing commercial entrance, or only new construction?
+
Both. We install this hardware in new fit-outs like this clinic and retrofit it into existing commercial entrances that need to meet accessibility requirements.
What happens if the paddle stops opening the door?
+
Usually a wiring or relay issue at the switching network rather than the paddle itself. We can typically diagnose and fix it through automatic door repair in a single visit.
Related Reading

From the blog